Catheter Access Port Kits for use with Medtronic Implantable Infusion Pumps instructions for use.
This reference manual contains information specifically regarding indications, drug stability and emergency procedures for the SynchroMed® and IsoMed® Infusion Systems.
This implant manual includes the instructions for use for the Indura® 1P model 8709SC.
This implant manual includes the instructions for use for the Intrathecal Catheter and Sutureless Connector model 8731SC.
This manual presents information for users of the N'Vision Clinician Programmer, model 8840 including an overview and description, as well as the use, maintenance, troubleshooting, and specifications of the Programmer.
Intructions for use for the Sutureless Pump Connector Revision Kit for model 8709 and model 8709SC intrathecal catheters.
This is the instructions for use for the SynchroMed EL Programmable drug infusion system model 8627.
This is the instructions for use for the SynchroMed EL Programmable drug infusion system model 8627.
Whenever there is a change in drug concentration or solution, the remaining old drug in the pump tubing and catheter must be accounted for to prevent under- or overdosing the patient while the old drug concentration is being cleared from the fluid pathway. This reference card outlines how to calculate a bridge bolus.
The existing implanted pump internal pump tubing, reservoir and any unrevised catheter segment are full of drug following a catheter revision. All unrevised spinal catheter segments must be aspirated. A priming bolus is programmed to advance the drug to the tip of the catheter. Before executing a priming bolus it is important to know the location of drug.
This card provides information on the identification of symptoms and suggestions for treatment for morphine Intrathecal/epidural overdose.
The existing implanted pump internal pump tubing and reservoir are full of drug following a catheter replacement. A priming bolus is programmed to advance drug to the tip of the catheter. Before executing a priming bolus it is important to know the location of drug.
This guide describes a low-complication catheter implant procedure for the 8709SC and 8731SC catheters.
This guide provides an overview of operating N'Vision software. Includes a description of programming parameters and calculations.
This guide provides an overview of how to operate the N'Vision Clinician Programmer.
The internal pump tubing and reservoir are filled with water during the manufacturing process. Before the drug is injected into the reservoir, the water is aspirated. At implant, a priming bolus is programmed to advance drug to the tip of the catheter. Before executing a priming bolus it is important to know the location of drug or other fluid in the system.
This is a supplement to the clinical reference guide and has detailed information about the sutureless connector.
SynchroMed EL programming guide for software application card model 8870 software version B.
Medtronic has confirmed through engineering analyses that the use of indicated and nonindicated drug formulations can result in collection of CSF protein in the catheter lumen, distal end. Although this may occur with any drug, nonindicated drug formulations can result in significantly increased collections of material in the catheter lumen resulting in complete occlusion of the catheter.
Medtronic has confirmed through returned product analysis that the use of nonindicated drug formulations can compromise the performance of the SynchroMed II and SynchroMed EL infusion systems. This paper discusses the mechanism by which nonindicated drug formations can cause corrosion to the pumps internal components, resulting in permanent motor stalls and therapy cessation.
This guide provides additional tips and pointers for programming SynchroMed II and SynchroMed EL infusion systems.