    SynchroMed II

    SynchroMed II Drug Infusion System Brief Summary

    Product technical manuals and the appropriate drug labeling must be reviewed prior to use for detailed disclosure.


    Indications:

    US: Chronic intraspinal (epidural and intrathecal) infusion of preservative-free morphine sulfate sterile solution in the treatment of chronic intractable pain, chronic intrathecal infusion of preservative-free ziconotide sterile solution for the management of severe chronic pain, and chronic intrathecal infusion of Lioresal® Intrathecal (baclofen injection) for the management of severe spasticity; chronic intravascular infusion of floxuridine (FUDR) or methotrexate for the treatment of primary or metastatic cancer. Outside of US: Chronic infusion of drugs or fluids tested as compatible and listed in the product labeling.


    Contraindications:

    Infection; implant depth greater than 2.5 cm below skin; insufficient body size; spinal anomalies; drugs with preservatives, drug contraindications, drug formulations with pH ≤3, use of catheter access port (CAP) kit for refills or of refill kit for catheter access, blood sampling through CAP in vascular applications, use of Personal Therapy Manager to administer opioid to opioid-naïve patients or to administer ziconotide.


    Warnings:

    Non-indicated formulations may contain neurotoxic preservatives, antimicrobials, or antioxidants, or may be incompatible with and damage the system. Failure to comply with all product instructions, including use of drugs or fluids not indicated for use with system, or of questionable sterility or quality, or use of non-Medtronic components or inappropriate kits, can result in improper use, technical errors, increased risks to patient, tissue damage, damage to the system requiring revision or replacement, and/or change in therapy, and may result in additional surgical procedures, a return of underlying symptoms, and/or a clinically significant or fatal drug under- or overdose. Refer to appropriate drug labeling for indications, contraindications, warnings, precautions, dosage and administration information, screening procedures and underdose and overdose symptoms and methods of management. Physicians must be familiar with the drug stability information in the product technical manuals and must understand the dose relationship to drug concentration and pump flow rate before prescribing pump infusion. Implantation and ongoing system management must be performed by individuals trained in the operation and handling of the infusion system. An inflammatory mass that can result in serious neurological impairment, including paralysis, may occur at the tip of the implanted catheter. Clinicians should monitor patients on intraspinal therapy carefully for any new neurological signs or symptoms, change in underlying symptoms, or need for rapid dose escalation.

    Inform patients of the signs and symptoms of drug under- or overdose, appropriate drug warnings and precautions regarding drug interactions, potential side effects, and signs and symptoms that require medical attention, including prodromal signs and symptoms of inflammatory mass. Failure to recognize signs and symptoms and seek appropriate medical intervention can result in serious injury or death. Instruct patients to notify their healthcare professionals of the implanted pump before medical tests/procedures, to return for refills at prescribed times, to carry their Medtronic device identification card, to avoid manipulating the pump through the skin, to consult with their clinician if the pump alarms and before traveling or engaging in activities that can stress the infusion system or involve pressure or temperature changes. Strong sources of electromagnetic interference (EMI), such as short wave (RF) diathermy and MRI, can negatively interact with the pump and cause heating of the implanted pump, system damage, or changes in pump operation or flow rate, that can result in patient injury from tissue heating, additional surgical procedures, a return of underlying symptoms, and/or a clinically significant or fatal drug underdose or overdose. Avoid using shortwave (RF) diathermy within 30 cm of the pump or catheter. Effects of other types of diathermy (microwave, ultrasonic, etc.) on the pump are unknown. Drug infusion is suspended during MRI; for patients who can not safely tolerate suspension, use alternative drug delivery method during MRI. Patients receiving intrathecal baclofen therapy are at higher risk for adverse events, as baclofen withdrawal can lead to a life threatening condition if not treated promptly and effectively. Confirm pump status before and after MRI. Reference product labeling for information on sources of EMI, effects on patient and system, and steps to reduce risks from EMI.


    Precautions:

    Monitor patients after device or catheter replacement for signs of underdose/overdose. Infuse preservative-free (intraspinal) saline or, for vascular applications, infuse heparinized solutions therapy at minimum flow rate if therapy is discontinued for an extended period of time to avoid system damage. EMI may interfere with programmer telemetry during pump programming sessions. EMI from the SynchroMed programmer may interfere with other active implanted devices (e.g., pacemaker, defibrillator, neurostimulator).


    Adverse Events:

    Include, but are not limited to, spinal/vascular procedure risks; infection; bleeding; tissue damage, damage to the system or loss of, or change in, therapy that may result in additional surgical procedures, a return of underlying symptoms, and/or a clinically significant or fatal drug underdose or overdose, due to end of device service life, failure of the catheter, pump or other system component, pump inversion, technical/programming errors, or improper use, including use of non-indicated formulations and/or not using drugs or system in accordance with labeling; pocket seroma, hematoma, erosion, infection; post-lumbar puncture (spinal headache); CSF leak and rare central nervous system pressure-related problems; hygroma; radiculitis; arachnoiditis; spinal cord bleeding/damage; meningitis; neurological impairment (including paralysis) due to inflammatory mass; potential serious adverse effects from catheter fragments in intrathecal space, including potential to compromise antibiotic effectiveness for CSF infection; anesthesia complications; body rejection phenomena; local and systemic drug toxicity and related side effects; potential serious adverse effects from catheter placement in intravascular applications.

    Lioresal® is a registered trademark of Medtronic, Inc.

    USA Rx Only

    Rev 0911

    SynchroMed EL

    SynchroMed EL Drug Infusion System Brief Summary:

    Product technical manual must be reviewed prior to use for full disclosure.


    Indications:

    US: Chronic intraspinal (epidural and intrathecal) infusion of preservative-free morphine sulfate sterile solution in the treatment of chronic intractable pain, chronic intrathecal infusion of preservative-free ziconotide sterile solution for the management of severe chronic pain, and chronic intrathecal infusion of Lioresal® Intrathecal (baclofen injection) for the management of severe spasticity; chronic intravascular infusion of floxuridine (FUDR) or methotrexate for the treatment of primary or metastatic cancer.


    Contraindications:

    When infection is present; when the pump cannot be implanted 2.5 cm or less from the surface of the skin; when body size is not sufficient to accept pump bulk and weight; when contraindications exist relating to the drug; drugs with preservatives.


    Warnings:

    Comply with all product instructions for initial preparation and filling, implantation, programming, refilling, and injecting into the catheter access port (CAP) of the pump. Failure to comply with all instructions can lead to technical errors or improper use of implanted infusion pumps and result in additional surgical procedures, a return of underlying symptoms, or a clinically significant or fatal drug under- or overdose. Refer to the appropriate drug labeling for specific under- or overdose symptoms and methods of management. Avoid using short wave (RF) diathermy within 30 cm of the pump or catheter. Diathermy may produce significant temperature rises in the area of the pump and continue to heat the tissue in a localized area. If overheated, the pump may over infuse the drug, potentially causing a drug overdose. Effects of other types of diathermy (microwave, ultrasonic, etc.) on the pump are unknown. An inflammatory mass that can result in serious neurological impairment, including paralysis, may occur at the tip of the implanted catheter. Clinicians should monitor patients on intraspinal therapy carefully for any new neurological signs or symptoms. For intraspinal therapy, use only preservative-free sterile solution indicated for intraspinal use. Use only Medtronic components indicated for use with this system. Failure to firmly secure connections can allow drug or cerebrospinal fluid (CSF) leakage into tissue and result in tissue damage or inadequate therapy. A postoperative priming bolus should not be programmed if the pump is a replacement and the catheter has not been aspirated.

    Refer to appropriate drug labeling for indications, contraindications, warnings, precautions, dosage and administration information, and screening procedures. Physicians must be familiar with the drug stability information in the technical manual and must understand the dose relationship to drug concentration and pump flow rate before prescribing pump infusion. Implantation and ongoing system management must be performed by individuals trained in the operation and handling of the infusion system.

    Inform patients of the signs and symptoms of drug under- or overdose, appropriate drug warnings and precautions regarding drug interactions, potential side effects, and signs and symptoms that require medical attention. Instruct patients to notify their clinician of travel plans, to return for refills at prescribed times, avoid activities such as strenuous exercise or contact sports that jar, impact, twist, or stretch the body, to always carry their Medtronic device identification card, to avoid manipulating the pump through the skin, and to notify healthcare professionals of the implanted pump before medical tests/procedures. Patients must consult their physician before engaging in activities involving pressure or temperature changes (e.g., scuba diving, saunas, hot tubs, hyperbaric chambers, flights, skydiving, etc.).


    Precautions:

    The pump is ethylene oxide sterilized. Do not use if the product or package is damaged, the sterile seal is broken, or the “Use By” date has expired. Do not reuse or resterilize the pump; it is intended for “single use only.” Do not expose the pump to temperatures above 43°C or below 5°C. Consider use of peri- and post-operative antibiotics for pump implantation, for any subsequent surgical procedure, or if infection is present. For patients prone to CSF leaks, clinicians should consider special procedures, such as a blood patch. Follow instructions for emptying and filling the pump during a replacement or revisions that require removal of the pump from the pocket. Explant the pump postmortem if incineration is planned (to avoid explosion), or if local environmental regulations mandate removal. Return explanted devices to Medtronic for analysis and safe disposal. Do not implant a pump dropped onto a hard surface or showing signs of damage. Implant the pump less than 2.5 cm from the surface of the skin. Ensure pump ports will be easy to access after implant, that the catheter is not kinked and secured well away from pump ports before suturing. Keep the implant site clean, dry, and protected from pressure or irritation. If therapy is discontinued for an extended period of time, fill the reservoir with preservative-free saline in intraspinal applications or appropriate heparinized solution (if not contraindicated) in vascular applications.

    The magnetic field or telemetry signals produced by the programmer may cause sensing problems and inappropriate device responses with an implantable pacemaker and/or defibrillator. Electromagnetic interference (EMI) is an energy field generated by equipment found in the home, work, medical, or public environments. Most EMI normally encountered will not affect the operation of the pump. Exceptions include: injury resulting from heating of the pump which can damage surrounding tissue (diathermy, MRI), system damage which can require surgical replacement or result in loss/change in symptom control (defibrillation, electrocautery, high-output ultrasonics, radiation therapy), and operational changes to the pump causing the motor to stop, loss of therapy, return of underlying symptoms, and require confirmation of pump function (diathermy, high magnetic field devices, hyperbaric/hypobaric conditions, magnetic resonance imaging (MRI)). MRI will temporarily stop the pump motor’s rotor due to the magnetic field of the MRI scanner and suspend drug infusion during MRI exposure. The pump should resume normal operation upon termination of MRI exposure. Prior to MRI, the physician should determine if the patient can safely be deprived of drug delivery. If not, alternative delivery methods for the drug can be utilized during the MRI scan. Prior to scheduling an MRI scan and upon its completion, pump status should be confirmed.


    Adverse Events:

    Include, but are not limited to, cessation of therapy due to end of device service life or component failure, change in flow performance due to component failure, inability to program the device due to programmer failure, CAP component failure; inaccessible refill port due to inverted pump, pocket seroma, hematoma, erosion, infection, post-lumbar puncture (spinal headache), CSF leak, radiculitis, arachnoiditis, bleeding, spinal cord damage, meningitis (intrathecal applications), anesthesia complications, damage to the pump, catheter and catheter access system due to improper handling and filling before, during, or after implantation; change in catheter performance due to catheter kinking, disconnection, leakage, breakage, occlusion, dislodgement, migration, or catheter fibrosis; body rejection phenomena, surgical replacement of pump or catheter due to complications; local and systemic drug toxicity and related side effects, complications due to use of unapproved drugs and/or not using drugs in accordance with drug labeling, or inflammatory mass at the tip of the catheter.

    Lioresal® is a registered trademark of Medtronic, Inc.

    USA Rx only

    Rev 0911

    IsoMed

    IsoMed Constant Flow Infusion System

    Product technical manuals and the appropriate drug labeling must be reviewed prior to use for detailed disclosure.


    Indications

    US: Chronic intrathecal infusion of preservative-free morphine sulfate sterile solution in the treatment of chronic intractable pain and chronic intravascular infusion of floxuridine (FUDR) for the treatment of primary or metastatic cancer. Outside of US: Chronic infusion of drugs or fluids tested as compatible and listed in the product labeling.


    Contraindications

    When infection is present; when the pump cannot be implanted 2.5 cm or less from the surface of the skin; when body size is not sufficient to accept pump bulk and weight; when contraindications exist relating to the drug; drugs with preservatives. Do not use the Personal Therapy Manager accessory to administer opioid to opioid-naïve patients or to administer ziconotide. Blood sampling through the catheter access port is contraindicated.


    Warnings

    Comply with all product instructions for initial preparation and filling, implantation, programming, refilling, and injecting into the catheter access port (CAP) of the pump. Failure to comply with all instructions can lead to technical errors or improper use of implanted infusion pumps and result in additional surgical procedures, a return of underlying symptoms, or a clinically significant or fatal drug underdose or overdose. Refer to the appropriate drug labeling for specific underdose or overdose symptoms and methods of management. Avoid using short wave (RF) diathermy within 30 cm of the pump or catheter. Diathermy may produce significant temperature rises in the area of the pump and continue to heat the tissue in a localized area. If overheated, the pump may over infuse the drug, potentially causing a drug overdose. Effects of other types of diathermy (microwave, ultrasonic, etc.) on the pump are unknown. An inflammatory mass that can result in serious neurological impairment, including paralysis, may occur at the tip of the implanted catheter. Clinicians should monitor patients on intraspinal therapy carefully for any new neurological signs or symptoms. For intraspinal therapy, use only preservative-free sterile solution indicated for intraspinal use. Use only Medtronic components indicated for use with this system. Failure to firmly secure connections can allow drug or cerebrospinal fluid (CSF) leakage into tissue and result in tissue damage or inadequate therapy. A postoperative priming bolus should not be programmed if the pump is a replacement and the catheter has not been aspirated. Refer to appropriate drug labeling for indications, contraindications, warnings, precautions, dosage and administration information, and screening procedures. Physicians must be familiar with the drug stability information in the technical manual and must understand the dose relationship to drug concentration and pump flow rate before prescribing pump infusion. Implantation and ongoing system management must be performed by individuals trained in the operation and handling of the infusion system. Inform patients of the signs and symptoms of drug underdose or overdose, appropriate drug warnings and precautions regarding drug interactions, potential side effects, and signs and symptoms that require medical attention. Instruct patients to notify their clinician of travel plans, to return for refills at prescribed times, avoid activities such as strenuous exercise or contact sports that jar, impact, twist, or stretch the body, to always carry their Medtronic device identification card, to avoid manipulating the pump through the skin, and to notify healthcare professionals of the implanted pump before medical tests/procedures. Patients must consult their physician before engaging in activities involving pressure or temperature changes (e.g., scuba diving, saunas, hot tubs, hyperbaric chambers, flights, skydiving, etc.) Inform patients that the SynchroMed pump has an Elective Replacement Indicator (ERI) that sounds when the pump is nearing its end of service. When the alarm sounds, patients must contact their doctor to schedule pump replacement.


    Precautions

    The pump is ethylene oxide sterilized. Do not use if the product or package is damaged, the sterile seal is broken, or the "Use By" date has expired. Do not reuse or resterilize the pump; it is intended for "single use only." Do not expose the pump to temperatures above 43°C or below 5°C. Consider use of peri- and post-operative antibiotics for pump implantation, for any subsequent surgical procedure, or if infection is present. For patients prone to CSF leaks, clinicians should consider special procedures, such as a blood patch. Follow instructions for emptying and filling the pump during a replacement or revisions that require removal of the pump from the pocket. Explant the pump postmortem if incineration is planned (to avoid explosion), or if local environmental regulations mandate removal. Return explanted devices to Medtronic for analysis and safe disposal. Do not implant a pump dropped onto a hard surface or showing signs of damage. Implant the pump less than 2.5 cm from the surface of the skin. Ensure pump ports will be easy to access after implant, that the catheter is not kinked and secured well away from pump ports before suturing. Keep the implant site clean, dry, and protected from pressure or irritation. If therapy is discontinued for an extended period of time, fill the reservoir with preservative-free saline in intraspinal applications or appropriate heparinized solution (if not contraindicated) in vascular applications.

    Electromagnetic interference (EMI) is an energy field generated by equipment found in the home, work, medical, or public environments. Most EMI normally encountered will not affect the operation of the pump. Exceptions include: injury resulting from heating of the pump which can damage surrounding tissue (diathermy, MRI), SynchroMed system damage which can require surgical replacement or result in loss/change in symptom control (defibrillation, electrocautery, high-output ultrasonics, radiation therapy), and operational changes to the SynchroMed pump causing the motor to stop, loss of therapy, return of underlying symptoms, and require confirmation of pump function (diathermy, high magnetic field devices, hyperbaric/hypobaric conditions, magnetic resonance imaging (MRI)). MRI will temporarily stop the SynchroMed pump motor's rotor due to the magnetic field of the MRI scanner and suspend drug infusion during MRI exposure which will cause the pump alarm to sound. The pump should resume normal operation upon termination of MRI exposure. Prior to MRI, the physician should determine if the patient can safely be deprived of drug delivery. If not, alternative delivery methods for the drug can be utilized during the MRI scan. Prior to scheduling an MRI scan and upon its completion, SynchroMed pump status should be confirmed. The magnetic field or telemetry signals produced by the SynchroMed programmer may cause sensing problems and inappropriate device responses with an implantable pacemaker and/or defibrillator.


    Adverse Events

    Include, but are not limited to, spinal/vascular procedure risks; infection; bleeding; tissue damage, damage to the system or loss of, or change in, therapy that may result in additional surgical procedures, a return of underlying symptoms, and/or a clinically significant or fatal drug underdose or overdose, due to end of device service life, failure of the catheter, pump or other system component, pump inversion, technical/programming errors, or improper use, including use of non-indicated formulations and/or not using drugs or system in accordance with labeling; pocket seroma, hematoma, erosion, infection; post-lumbar puncture (spinal headache); CSF leak and rare central nervous system pressure-related problems; hygroma; radiculitis; arachnoiditis; spinal cord bleeding/damage; meningitis; neurological impairment (including paralysis) due to inflammatory mass; potential serious adverse effects from catheter fragments in intrathecal space, including potential to compromise antibiotic effectiveness for CSF infection; anesthesia complications; body rejection phenomena; local and systemic drug toxicity and related side effects; potential serious adverse effects from catheter placement in intravascular applications.

    USA Rx only

    Rev 0209